{"title":"6077-Analytical","description":"","products":[{"product_id":"column-chromegabond-c6-150-mm-4-6-mm-id-5-mm","title":"Column, ChromegaBond C6, 150 mm, 4.6 mm ID, 5 μm","description":" ","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53609989800227,"sku":"B135211C6","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/perkinelmer-logo_20800x800_20100dpi.png?v=1752951604"},{"product_id":"brownlee-spheri-5-c18-conventional-column-250-mm-x-4-6-mm-i-d-5um","title":"Brownlee Spheri-5 C18 Conventional Column - 250 mm x 4.6 mm I.D., 5µm","description":"\u003cp class=\"richp\"\u003e\r\u003c\/p\u003e\u003cp class=\"richp\"\u003eThe Brownlee Spheri® C18 ODS column contains a small-pore, silica-based sorbent for separating small molecules. The C18 is the most retentive reverse-phase in this family. This conventional Brownlee column (non-cartridge) uses standard compression end fittings compatible with all HPLC instrumentation and only requires a holder when used with a NewGuard cartridge. To couple a conventional column to a NewGuard cartridge, a NewGuard holder is necessary.\r\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEnd-Capping: Yes\r\u003c\/li\u003e\n\u003cli\u003eCarbon Load: 11%\r\u003c\/li\u003e\n\u003cli\u003eInteraction Mode: Reversed Phase\r\u003c\/li\u003e\n\u003cli\u003epH Range: 2.5-8.0\r\u003c\/li\u003e\n\u003cli\u003eTemperature Limit: 60℃\r\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53609995272483,"sku":"BCS1851","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Perkin_Elmer_BCS1851.png?v=1756497286"},{"product_id":"brownlee-pecosphere-ra-c8-cartridge-column-33-mm-x-4-6-mm-i-d-3-mm","title":"Brownlee Pecosphere RA C8 Cartridge Column - 33 mm x 4.6 mm I.D., 3 μm","description":"\u003cspan style=\"color: rgb(64, 64, 64); font-family: Roboto, sans-serif; font-size: 16px; background-color: rgb(255, 255, 255);\"\u003eBrownlee Pecosphere RA C8 columns are packed with rugged, high purity silica with standard end-capping for the analysis of increasingly basic analytes. These cartridge-style columns require the 33 mm fast LC Pecosphere cartridge holder.\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003eQuantity: Package of 5\u003c\/li\u003e\n\u003cli\u003eEnd-Capping: Yes\u003c\/li\u003e\n\u003cli\u003eCarbon Load: 5%\u003c\/li\u003e\n\u003cli\u003eInteraction Mode: Reversed Phase\u003c\/li\u003e\n\u003cli\u003epH Range: 2.0-8.0\u003c\/li\u003e\n\u003cli\u003eSurface Area: 200 m\u003cspan style=\"box-sizing: border-box; font-size: 10.2px; position: relative; line-height: 0; vertical-align: baseline; top: -0.5em;\"\u003e2\u003c\/span\u003e\/g\u003c\/li\u003e\n\u003cli\u003eUSP Code: L7\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53610041737507,"sku":"BGR0831","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/perkinelmer-logo_20800x800_20100dpi_edf8d201-6bf6-43b5-be64-0606c3b582cd.png?v=1752952545"},{"product_id":"brownlee-aquapore-ax-300-column-100-mm-x-4-6-mm-id-7-0-um","title":"Brownlee Aquapore AX-300 Column - 100 mm x 4.6 mm ID, 7.0 µm","description":"\u003cp class=\"richp\"\u003e\n\u003c\/p\u003e\u003cp class=\"richp\"\u003eThe Brownlee Aquapore® AX-300 column is built on large pore silica for improved retention and resolution compared to traditional silica. This column is a weak anion exchanger composed of a crosslinked polyethyleneimine phase bonded on the silica surface. Conventional Brownlee columns (non-cartridge) use standard compression end fittings compatible with all HPLC instrumentation and do not require holders unless they are being used with a NewGuard cartridge. To couple a conventional column to a NewGuard cartridge, a NewGuard holder is necessary.\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInteraction Mode: Ion Exchange\n\u003c\/li\u003e\n\u003cli\u003epH Range: 2.0-8.0\n\u003c\/li\u003e\n\u003cli\u003eTemperature Limit: 60°C\n\u003c\/li\u003e\n\u003cli\u003eUSP Code: L14\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53610054287651,"sku":"BRA2673","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Perkin_Elmer_BRA2673.png?v=1756498081"},{"product_id":"brownlee-polypore-h-cartridge-column-220-mm-x-4-6-mm-id-10um","title":"Brownlee Polypore H Cartridge Column - 220 mm x 4.6 mm ID, 10 µm","description":"\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThe Brownlee Polypore\u003cspan style=\"box-sizing: border-box; font-size: 9.6px; position: relative; line-height: 0; vertical-align: baseline; top: -0.5em;\"\u003e®\u003c\/span\u003e H cartridge columns is a microporous, polymer-based column with a hydrogen counter ion.\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThis cartridge column requires a holder:\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eTo use with a guard - 220 mm NewGuard System Holder (07150017)\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eTo use without without a guard - 220 mm MPLC Holder (07150015)\u003c\/p\u003e\u003cul style=\"box-sizing: border-box; margin: 0px 1.1em 1.1em; padding: 0px 0px 0px 20px; line-height: 1.6; list-style-position: outside; position: relative; left: 1.1em; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; font-size: 16px; background-color: rgb(255, 255, 255);\"\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eInteraction Mode: Ion Exchange\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003epH Range: 1.0-14.0\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eTemperature Limit: 90°C\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eUSP Code: L17\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53610054484259,"sku":"BRP4615","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Perkin_Elmer_BRP4615.png?v=1756498085"},{"product_id":"cartridge-spheri-5-rp-8-2-1-x-100-mm-5-um","title":"Cartridge, Spheri-5, RP-8, 2.1 x 100 mm, 5 µm","description":" ","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53610054746403,"sku":"BRS0854","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/perkinelmer-logo_20800x800_20100dpi_b2e286aa-5f1e-4d91-80c7-be0ce4eb21d7.png?v=1752952702"},{"product_id":"brownlee-spheri-5-rp-8-cartridge-column-220-mm-x-2-1-mm-id-5-0-um","title":"Brownlee Spheri-5 RP-8 Cartridge Column - 220 mm x 2.1 mm ID, 5.0 µm","description":"\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThe Brownlee Spheri-5\u003cspan style=\"box-sizing: border-box; font-size: 9.6px; position: relative; line-height: 0; vertical-align: baseline; top: -0.5em;\"\u003e™\u003c\/span\u003e RP-8 cartridge column has a small-pore, silica-based sorbent, optimized for separating small molecules. Also available in a 10 μm particle size (Spheri-10\u003cspan style=\"box-sizing: border-box; font-size: 9.6px; position: relative; line-height: 0; vertical-align: baseline; top: -0.5em;\"\u003e®\u003c\/span\u003e).\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThis cartridge column requires a holder:\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eTo use with a guard - 220 mm NewGuard System Holder (07150017)\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eTo use without without a guard - 220 mm MPLC Holder (07150015)\u003c\/p\u003e\u003cul style=\"box-sizing: border-box; margin: 0px 1.1em 1.1em; padding: 0px 0px 0px 20px; line-height: 1.6; list-style-position: outside; position: relative; left: 1.1em; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; font-size: 16px; background-color: rgb(255, 255, 255);\"\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eEnd-Capping: Yes\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eCarbon Load: 6%\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eInteraction Mode: Reversed Phase\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003epH Range: 2.5-8.0\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eTemperature Limit: 60°C\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eUSP Code: L7\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53610054779171,"sku":"BRS0856","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Perkin_Elmer_BRS0856.png?v=1756498028"},{"product_id":"brownlee-spheri-5-rp-18-cartridge-column-220-mm-x-4-6-mm-id-5-0-um","title":"Brownlee Spheri-5 RP-18 Cartridge Column - 220 mm x 4.6 mm ID, 5.0 µm","description":"\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThe Brownlee Spheri-5\u003cspan style=\"box-sizing: border-box; font-size: 9.6px; position: relative; line-height: 0; vertical-align: baseline; top: -0.5em;\"\u003e®\u003c\/span\u003e RP-18 cartridge column has a small-pore, silica-based sorbent, optimized for separating small molecules. Also available in a 10 μm particle size (Spheri-10\u003cspan style=\"box-sizing: border-box; font-size: 9.6px; position: relative; line-height: 0; vertical-align: baseline; top: -0.5em;\"\u003e®\u003c\/span\u003e).\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThis cartridge column requires a holder:\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eTo use with a guard - 220 mm NewGuard System Holder (07150017)\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eTo use without without a guard - 220 mm MPLC Holder (07150015)\u003c\/p\u003e\u003cul style=\"box-sizing: border-box; margin: 0px 1.1em 1.1em; padding: 0px 0px 0px 20px; line-height: 1.6; list-style-position: outside; position: relative; left: 1.1em; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; font-size: 16px; background-color: rgb(255, 255, 255);\"\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eEnd-Capping: Yes\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eCarbon Load: 11%\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eInteraction Mode: Reversed Phase\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003epH Range: 2.5-8.0\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eTemperature Limit: 60°C\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eUSP Code: L1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53610054844707,"sku":"BRS1813","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Perkin_Elmer_Brownlee_Column.png?v=1756498033"},{"product_id":"brownlee-spheri-5-rp-18-cartridge-column-220-mm-x-2-1-mm-id-5-0-um","title":"Brownlee Spheri-5 RP-18 Cartridge Column - 220 mm x 2.1 mm ID, 5.0 µm","description":"\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThe Brownlee Spheri-5\u003cspan style=\"box-sizing: border-box; font-size: 9.6px; position: relative; line-height: 0; vertical-align: baseline; top: -0.5em;\"\u003e®\u003c\/span\u003e RP-18 cartridge column has a small-pore, silica-based sorbent, optimized for separating small molecules. Also available in a 10 μm particle size (Spheri-10\u003cspan style=\"box-sizing: border-box; font-size: 9.6px; position: relative; line-height: 0; vertical-align: baseline; top: -0.5em;\"\u003e®\u003c\/span\u003e).\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThis cartridge column requires a holder:\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eTo use with a guard - 220 mm NewGuard System Holder (07150017)\u003c\/p\u003e\u003cp style=\"box-sizing: border-box; font-size: 16px; line-height: 1.4; margin: 0px 0px 1rem; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; background-color: rgb(255, 255, 255);\"\u003eTo use without without a guard - 220 mm MPLC Holder (07150015)\u003c\/p\u003e\u003cul style=\"box-sizing: border-box; margin: 0px 1.1em 1.1em; padding: 0px 0px 0px 20px; line-height: 1.6; list-style-position: outside; position: relative; left: 1.1em; color: rgb(64, 64, 64); font-family: Roboto, sans-serif; font-size: 16px; background-color: rgb(255, 255, 255);\"\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eEnd-Capping: Yes\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eCarbon Load: 11%\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eInteraction Mode: Reversed Phase\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003epH Range: 2.5-8.0\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eTemperature Limit: 60°C\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; font-size: 17px; line-height: 1.5;\"\u003eUSP Code: L1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Perkin Elmer","offers":[{"title":"Default Title","offer_id":53610054910243,"sku":"BRS1856","price":0.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Perkin_Elmer_BRS1856.png?v=1756498037"},{"product_id":"column-orosil-c18-250-x-4-6mm-3um","title":"Column, Orosil C18, 250 x 4.6mm 3µm","description":" ","brand":"Orochem","offers":[{"title":"Default Title","offer_id":53610362634531,"sku":"C61O3HI902","price":1154.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/orochem_hplc_column.jpg?v=1752957428"},{"product_id":"column-orosil-c18-150-x-4-6-mm-5-um","title":"Column, Orosil C18, 150 x 4.6 mm, 5 µm","description":" ","brand":"Orochem","offers":[{"title":"Default Title","offer_id":53610362700067,"sku":"C61O5FI903","price":1106.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/orochem_hplc_column_8b071b0c-9cbb-41db-b902-ef4335ec2118.jpg?v=1752957432"},{"product_id":"column-acclaim-c18-120a-150-x-4-6-mm-5-um","title":"Column, Acclaim C18, 120Å, 150 x 4.6 mm, 5 µm","description":null,"brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610967793955,"sku":"CK059148","price":1309.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_7d740790-d09b-4d33-88d4-d9563b81a50c.jpg?v=1774548676"},{"product_id":"column-acclaim-polar-advantage-ii-120a-100-x-2-1-mm-2-2-um","title":"Column, Acclaim Polar Advantage II, 120Å, 100 x 2.1 mm, 2.2 µm","description":null,"brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610968121635,"sku":"CK068990","price":1658.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_a5f32e51-78c2-479c-b347-c452199170c0.jpg?v=1774548710"},{"product_id":"column-accucore-phenyl-hexyl-100-x-2-1-mm-2-6-um","title":"Column, Accucore Phenyl-Hexyl, 100 x 2.1 mm, 2.6 µm","description":null,"brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610971660579,"sku":"CK17926102130","price":1385.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_63eda0ee-044a-452f-8ead-daa052f1aaa6.jpg?v=1774548799"},{"product_id":"hypersil-gold-vanquish-c18-uhplc-column-100-x-2-1-mm-1-9-um","title":"Hypersil GOLD™ VANQUISH™ C18 UHPLC Column, 100 x 2.1 mm, 1.9 µm","description":"\u003cp class=\"richp\"\u003e\n\u003c\/p\u003e\u003cp class=\"richp\"\u003e\n\u003c\/p\u003e\u003cp class=\"richp\"\u003e\n\u003c\/p\u003e\u003cp class=\"richp\"\u003e\n\u003c\/p\u003e\u003cp class=\"richp\"\u003eAchieve even greater power of separation, speed, and throughput using Thermo Scientific™ Hypersil GOLD™ VANQUISH™ C18 UHPLC columns. \u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"richp\"\u003eThese reversed-phase columns were developed in conjunction with the Vanquish UHPLC system to take advantage of the system's extended pressure capabilities and robustness. The result is a new level of separation, speed and throughput that solve analytical challenges of analyzing complex matrices using liquid chromatography (LC) and LC-MS.\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610973888803,"sku":"CK25002102130V","price":1959.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_ae2dc4a2-6159-43a1-ba2b-9294baa23eff.jpg?v=1774548663"},{"product_id":"hypersil-gold-c18-selectivity-column-150-x-2-1-mm-3-um","title":"Hypersil GOLD™ C18 Selectivity Column, 150 x 2.1 mm, 3 µm","description":" ","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610974314787,"sku":"CK25003152130","price":1606.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/25002-051030-lc-hypersil-gold-c18-2869x2055.jpg-650.jpg?v=1752969157"},{"product_id":"hypersil-gold-aq-c18-polar-endcapped-hplc-column-100-x-2-1-mm-3-um","title":"Hypersil GOLD™ aQ C18 Polar Endcapped HPLC Column, 100 x 2.1 mm, 3 µm","description":"\u003cp class=\"richp\"\u003eRetain and resolve polar analytes using Thermo Scientific™ Hypersil GOLD™ aQ Polar Endcapped C18 columns. These columns provide excellent peak shape, even with challenging reversed phase separations using highly aqueous mobile phases.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eAlternative selectivity with polar endcapped C18 stationary phase\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePolar functional group in endcap provides additional interaction mechanism for separation of polar compounds\u003c\/li\u003e\n\u003cli\u003eYields superior retention of polar compounds\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eStability in highly aqueous mobile phases\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUsable in 100% aqueous mobile phases\u003c\/li\u003e\n\u003cli\u003eNo loss of performance or stability\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eExcellent peak shape\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eControlled secondary interactions ensure optimal peak shape for all analyte types\u003c\/li\u003e\n\u003cli\u003eIdeal for the quantitative analysis of trace levels of polar analytes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610975166755,"sku":"CK25303102130","price":1521.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_dbae2d02-4e23-4802-9462-b63e59ef23d3.jpg?v=1774548740"},{"product_id":"hypersil-bds-c18-column-125-x-4-6-mm-5-um-made-to-order-item","title":"Hypersil™ BDS C18 Column, 125 x 4.6 mm, 5 µm, Made-to-Order Item","description":"\u003cp class=\"richp\"\u003eFor a robust, general-purpose column to use in a wide range of applications, choose Thermo Scientific™ Hypersil™ BDS C18 HPLC Columns. These economical columns feature reduced silanol activity and provide exceptional reliability for QA\/QC labs. Built on the renowned Hypersil silica backbone, the base-deactivated silica is one of the most popular packing materials available.\r\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"richp\"\u003eFor more challenging separations that require improved chromatographic performance, use Thermo Scientific™ Hypersil GOLD™ columns as an alternative.\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610985357603,"sku":"CK28105124630","price":1496.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_9c49f3c9-b33f-4f5b-8779-7c84140e3ee5.jpg?v=1774548868"},{"product_id":"column-hypersil-silica-250-x-250-x-4-6-mm-5-um","title":"Hypersil™ Silica HPLC Column, 250 x 4.6 mm, 5 µm","description":" ","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610991616291,"sku":"CK30005254630","price":1575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_890d31a5-e825-4be8-ae47-bb6813c7fcf5.jpg?v=1774548997"},{"product_id":"column-hypersil-ods-125-x-4-mm-3-um","title":"Column, Hypersil ODS, 125 x 4 mm, 3 µm","description":null,"brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610991878435,"sku":"CK30103124030","price":1579.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_2f07d079-870d-47fb-8781-151770f6b454.jpg?v=1774549018"},{"product_id":"hypercarb-porous-graphitic-carbon-hplc-column-100-x-2-1-mm-5-um","title":"Hypercarb™ Porous Graphitic Carbon HPLC Column, 100 x 2.1 mm, 5 µm","description":"\u003cp class=\"richp\"\u003eHypercarb™ Porous Graphitic Carbon HPLC Columns\u003c\/p\u003e\u003cp class=\"richp\"\u003eOffer 100% porous graphitic carbon for extended separation capabilities with Thermo Scientific™ Hypercarb™ Porous Graphitic Carbon LC Columns. Enhanced retention of polar compounds and separation of structurally related analytes with stability at pH extremes and high temperature.\u003c\/p\u003e\u003cp class=\"richp\"\u003eSuited to solve problem separations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eExceptional retention of very polar analytes\u003c\/li\u003e\n\u003cli\u003eTrue orthoganality to C18\u003c\/li\u003e\n\u003cli\u003eSeparated structurally related substances\u003c\/li\u003e\n\u003cli\u003epH stable from 0 to 14\u003c\/li\u003e\n\u003cli\u003eExcellent for high temperature applications\u003c\/li\u003e\n\u003cli\u003e100% stainless-steel column hardware\u003c\/li\u003e\n\u003cli\u003ePEEK-free column hardware for use at temperatures above 120°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53610999775523,"sku":"CK35005102130","price":2862.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_34060212-b6aa-4b18-8e34-5fbecf915759.jpg?v=1774548942"},{"product_id":"accucore-xl-c8-hplc-column-50-x-3-0-mm-4-um","title":"Accucore™ XL C8 HPLC Column, 50 x 3.0 mm, 4 µm","description":"\u003cspan style=\"color: rgb(34, 34, 34); font-family: HelveticaNeue, sans-serif; font-size: 16px;\"\u003eOptimize conventional HPLC methods with Thermo Scientific™ Accucore™ XL C8 columns. Rugged 4µm solid-core particles ensure very high efficiencies within standard HPLC pressure limits. The high coverage C8 bonded phase provides optimal retention of analytes with moderate hydrophobicity. Robust bonding technology and automated packing procedures ensure excellent reproducibility and long column lifetimes.\u003c\/span\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":53611032412451,"sku":"CK74204053030","price":1389.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/Thermo_20Scientific_20Logo_202048x2048pxl_16e8e24f-6bb4-455a-b172-ad770e34bbe8.jpg?v=1774549260"},{"product_id":"inertsil-sil-100a-analytical-column-250-x-4-6-mm-5-um","title":"Inertsil SIL-100A Analytical Column, 250 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil SIL-100A is a pure silica gel column available in normal phase mode. Because of the high quality of its silica gel, Inertsil SIL-100A achievs separation with sharp peaks and provides high column-to-column reproducibility. This excellent silica gel ideally designed for HPLC is the basis for “Inertsil 3-series” of GL Sciences. GL Sciences is the first company which emphasized the importance of silica-gel purity and determined the nature of the silanol impurities in the Silica gel.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm \u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \u003c\/li\u003e\n\u003cli\u003eFunctional Group: None \u003c\/li\u003e\n\u003cli\u003eEnd-capping: None \u003c\/li\u003e\n\u003cli\u003eCarbon Loading: - % \u003c\/li\u003e\n\u003cli\u003eUSP Code: L3 \u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911376163,"sku":"GLS502001712","price":729.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0005760_inertsil-ods-3.png?v=1753023226"},{"product_id":"inertsil-ods-3-hplc-column-150-x-4-6-mm-5-um","title":"Inertsil ODS-3 HPLC Column, 150 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil ODS-3 is still GL Sciences’ most popular phase and continues to be used world widely and reliably for long established methods in pharmaceutical, and contract research labs. Inertsil ODS-3 has a relatively strong retentivity compared to commercially available ODS columns. In addition, the introduction of higher surface area silica provide high preparative loading capacity without sacrificing peak shape.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel\u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm)\u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 15.0 %\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1\u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911408931,"sku":"GLS502001731","price":630.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0005760_inertsil-ods-3_6926afd0-75c1-47f7-95ab-cb3cc62d84d2.png?v=1753023230"},{"product_id":"inertsil-ods-3-hplc-column-150-x-2-1-mm-5-um","title":"Inertsil ODS-3 HPLC Column, 150 x 2.1 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil ODS-3 is still GL Sciences’ most popular phase and continues to be used world widely and reliably for long established methods in pharmaceutical, and contract research labs. Inertsil ODS-3 has a relatively strong retentivity compared to commercially available ODS columns. In addition, the introduction of higher surface area silica provide high preparative loading capacity without sacrificing peak shape.\r\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \r\u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \r\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \r\u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \r\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \r\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \r\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 15.0 % \r\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \r\u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911441699,"sku":"GLS502001741","price":630.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0005760_inertsil-ods-3_2d5992eb-08e2-47e8-9ce4-6dc831d05bd8.png?v=1753023234"},{"product_id":"inertsil-ods-3-hplc-column-250-x-4-6-mm-3-um","title":"Inertsil ODS-3 HPLC Column, 250 x 4.6 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil ODS-3 is still GL Sciences’ most popular phase and continues to be used world widely and reliably for long established methods in pharmaceutical, and contract research labs. Inertsil ODS-3 has a relatively strong retentivity compared to commercially available ODS columns. In addition, the introduction of higher surface area silica provide high preparative loading capacity without sacrificing peak shape.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFunctional Group\u003c\/li\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \u003c\/li\u003e\n\u003cli\u003eParticle Size:  3 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 15.0 % \u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911507235,"sku":"GLS502001772","price":825.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0005760_inertsil-ods-3_4159a48c-fc46-4c9a-8350-4532b09b0851.png?v=1753023242"},{"product_id":"inertsil-ods-3v-hplc-column-150-x-4-6-mm-5-um","title":"Inertsil ODS-3V HPLC Column, 150 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil ODS-3V offers all of the outstanding chromatographic benefits of Inertsil ODS-3 with the added benefit of a more thoroughly documented, validated QC procedure consistent with the demands of GLP\/GMP compliance. Each Inertsil ODS-3V is delivered with a Manufacturer‘s Validation Certificate showing the detailed results of every QA and QC step in manufacturing. The use of Inertsil ODS-3V columns provides an extra measure of assurance of consistent performance from column to column and batch to batch. Inertsil ODS-3V columns are also available in 3-column-sets packed with your choice of 3 different silica batches or a single silica batch to assist in reproducibility studies.\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \n\u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm \n\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \n\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \n\u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \n\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \n\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \n\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 15.0 % \n\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \n\u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911540003,"sku":"GLS502001801","price":665.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002790_inertsil-ods-3v.png?v=1753023251"},{"product_id":"inertsil-ods-3v-hplc-column-250-x-4-6-mm-5-um","title":"Inertsil ODS-3V HPLC Column, 250 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil ODS-3V offers all of the outstanding chromatographic benefits of Inertsil ODS-3 with the added benefit of a more thoroughly documented, validated QC procedure consistent with the demands of GLP\/GMP compliance. Each Inertsil ODS-3V is delivered with a Manufacturer‘s Validation Certificate showing the detailed results of every QA and QC step in manufacturing. The use of Inertsil ODS-3V columns provides an extra measure of assurance of consistent performance from column to column and batch to batch. Inertsil ODS-3V columns are also available in 3-column-sets packed with your choice of 3 different silica batches or a single silica batch to assist in reproducibility studies.\r\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \r\u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm \r\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \r\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \r\u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \r\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \r\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \r\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 15.0 % \r\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \r\u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911572771,"sku":"GLS502001802","price":760.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002790_inertsil-ods-3v_3e82bff4-1bc8-4048-8eaa-06c6a638bf23.png?v=1753023254"},{"product_id":"inertsil-c8-3-hplc-column-150-x-4-6-mm-5-um","title":"Inertsil C8-3 HPLC Column, 150 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eThe same base silica gel and bonding technology that is used for Inertsil ODS-3 is also employed for Inertsil C8-3. The difference between the two phases is just the length of the hydrocarbon ligands. 10 μm particle size columns are also available to meet the requirement of various pharmacopeia methods. We recommend InertSustain C8 columns for all new method development.\r\u003c\/p\u003e\u003cp class=\"richp\"\u003eBase Material: 3 Series High Purity Silica Gel \r\u003c\/p\u003e\u003cp class=\"richp\"\u003eParticle Size:  5 µm\u003c\/p\u003e\u003cp class=\"richp\"\u003eSurface Area: 450 m2\/g \r\u003c\/p\u003e\u003cp class=\"richp\"\u003ePore Size: 100 Å (10 nm) \r\u003c\/p\u003e\u003cp class=\"richp\"\u003ePore Volume: 1.05 mL\/g \r\u003c\/p\u003e\u003cp class=\"richp\"\u003eFunctional Group: Octyl \r\u003c\/p\u003e\u003cp class=\"richp\"\u003eEnd-capping: Yes \r\u003c\/p\u003e\u003cp class=\"richp\"\u003eCarbon Loading: 9.0 % \r\u003c\/p\u003e\u003cp class=\"richp\"\u003eUSP Code: L7 \r\u003c\/p\u003e\u003cp class=\"richp\"\u003epH Range: 2 - 7.5\u003c\/p\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911638307,"sku":"GLS502001900","price":630.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002796_inertsil-c8-3.png?v=1753023259"},{"product_id":"inertsil-c8-3-hplc-column-250-x-4-6-mm-5-um","title":"Inertsil C8-3 HPLC Column, 250 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eThe same base silica gel and bonding technology that is used for Inertsil ODS-3 is also employed for Inertsil C8-3. The difference between the two phases is just the length of the hydrocarbon ligands. 10 μm particle size columns are also available to meet the requirement of various pharmacopeia methods. We recommend InertSustain C8 columns for all new method development.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octyl \u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 9.0 % \u003c\/li\u003e\n\u003cli\u003eUSP Code: L7 \u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911671075,"sku":"GLS502001901","price":729.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002796_inertsil-c8-3_eb01cbb1-8d56-4368-bc81-b020f437ea45.png?v=1753023263"},{"product_id":"inertsil-c8-3-analytical-column-150-x-4-6-mm-3-um","title":"Inertsil C8-3 Analytical Column, 150 x 4.6 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eThe same base silica gel and bonding technology that is used for Inertsil ODS-3 is also employed for Inertsil C8-3. The difference between the two phases is just the length of the hydrocarbon ligands. 10 μm particle size columns are also available to meet the requirement of various pharmacopeia methods. We recommend InertSustain C8 columns for all new method development.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \u003c\/li\u003e\n\u003cli\u003eParticle Size: 2 µm, 3 µm, 5 µm, 10 µm \u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octyl \u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 9.0 % \u003c\/li\u003e\n\u003cli\u003eUSP Code: L7 \u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911703843,"sku":"GLS502001911","price":717.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002796_inertsil-c8-3_8d3ac374-5d22-4312-a9d1-dc83d067020e.png?v=1753023266"},{"product_id":"inertsil-ods-4-analytical-hplc-column-250-x-4-0-mm-5-um","title":"Inertsil ODS-4 Analytical HPLC Column, 250 x 4.0 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil ODS-4 delivers the same extreme inertness to any type of compounds just like InertSustain C18 along with unprecedented stability under 100 % aqueous mobile phases for qualitative and quantitative analysis. However, as the base silica gel and carbon loading are different on Inertsil ODS-4, differences in selectivity can be observed for certain analytes.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm \u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 11.0 % \u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911736611,"sku":"GLS502003936","price":729.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002791_inertsil-ods-4.png?v=1753023275"},{"product_id":"inertsil-ods-4-analytical-hplc-column-250-x-4-6-mm-5-um","title":"Inertsil ODS-4 Analytical HPLC Column, 250 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil ODS-4 delivers the same extreme inertness to any type of compounds just like InertSustain C18 along with unprecedented stability under 100 % aqueous mobile phases for qualitative and quantitative analysis. However, as the base silica gel and carbon loading are different on Inertsil ODS-4, differences in selectivity can be observed for certain analytes.\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \n\u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm \n\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \n\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \n\u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \n\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \n\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \n\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 11.0 % \n\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \n\u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911769379,"sku":"GLS502003946","price":729.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002790_inertsil-ods-3v_4d883c7f-cfcb-4ec7-bfb6-880e0224df92.png?v=1753023283"},{"product_id":"inertsil-ods-4-hplc-column-150-x-2-1-mm-3-um","title":"Inertsil ODS-4 HPLC Column, 150 x 2.1 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil ODS-4 delivers the same extreme inertness to any type of compounds just like InertSustain C18 along with unprecedented stability under 100 % aqueous mobile phases for qualitative and quantitative analysis. However, as the base silica gel and carbon loading are different on Inertsil ODS-4, differences in selectivity can be observed for certain analytes.\n\u003c\/p\u003e\u003cp class=\"richp\"\u003e\n\u003c\/p\u003e\u003cp class=\"richp\"\u003eBase Material: 3 Series High Purity Silica Gel \n\u003c\/p\u003e\u003cp class=\"richp\"\u003eParticle Size: 3 µm\u003c\/p\u003e\u003cp class=\"richp\"\u003eSurface Area: 450 m2\/g \n\u003c\/p\u003e\u003cp class=\"richp\"\u003ePore Size: 100 Å (10 nm) \n\u003c\/p\u003e\u003cp class=\"richp\"\u003ePore Volume: 1.05 mL\/g \n\u003c\/p\u003e\u003cp class=\"richp\"\u003eFunctional Group: Octadecyl \n\u003c\/p\u003e\u003cp class=\"richp\"\u003eEnd-capping: Yes \n\u003c\/p\u003e\u003cp class=\"richp\"\u003eCarbon Loading: 11.0 % \n\u003c\/p\u003e\u003cp class=\"richp\"\u003eUSP Code: L1 \n\u003c\/p\u003e\u003cp class=\"richp\"\u003epH Range: 2 - 7.5\u003c\/p\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911802147,"sku":"GLS502004015","price":717.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002790_inertsil-ods-3v_4526ca80-ab00-415d-85f3-db6ff6f08b81.png?v=1753023288"},{"product_id":"inertsil-sil-100a-analytical-column-100-x-4-6-mm-3-um","title":"Inertsil SIL-100A Analytical Column, 100 x 4.6 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil SIL-100A is a pure silica gel column available in normal phase mode. Because of the high quality of its silica gel, Inertsil SIL-100A achievs separation with sharp peaks and provides high column-to-column reproducibility. This excellent silica gel ideally designed for HPLC is the basis for “Inertsil 3-series” of GL Sciences. GL Sciences is the first company which emphasized the importance of silica-gel purity and determined the nature of the silanol impurities in the Silica gel.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \u003c\/li\u003e\n\u003cli\u003eParticle Size: 3 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \u003c\/li\u003e\n\u003cli\u003eFunctional Group: None \u003c\/li\u003e\n\u003cli\u003eEnd-capping: None \u003c\/li\u003e\n\u003cli\u003eCarbon Loading: - % \u003c\/li\u003e\n\u003cli\u003eUSP Code: L3 \u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911834915,"sku":"GLS502004244","price":620.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0005760_inertsil-ods-3_f26d1410-3337-4f6e-9950-0d158dbf4265.png?v=1753023292"},{"product_id":"inertsil-nh2-analytical-column-100-x-3-0-mm-3-um","title":"Inertsil NH2 Analytical Column, 100 x 3.0 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil NH2 shows far superior stability compared to other brand available aminopropyl columns, as our newly developed \"Evolved Surface Silica\" is chemically bonded with aminopropyl group. Generally, aminopropyl columns are used for applications that are hard to be separated in a reversed phase mode, such as simultaneous analysis of sugars or vitamin E. However, the shift in retention time has been an issue for a long time. Inertsil NH2 delivers highly reliable reproducibility and stability with accurate qualitative and quantitative results. Furthermore, aminopropyl columns generally cannot be washed by weakly acidic eluent, however Inertsil NH2 was improved and it can be washed by weakly acidic eluent.\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel \n\u003c\/li\u003e\n\u003cli\u003eParticle size: 3 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g \n\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \n\u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \n\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Aminopropyl \n\u003c\/li\u003e\n\u003cli\u003eEnd-capping: None \n\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 8.0 % \n\u003c\/li\u003e\n\u003cli\u003eUSP Code: L8 \n\u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911867683,"sku":"GLS502005474","price":620.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002816_inertsil-nh2.png?v=1753023296"},{"product_id":"inertsil-nh2-analytical-column-150-x-4-6-mm-5-um","title":"Inertsil NH2 Analytical Column, 150 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp\u003eInertsil NH2 shows far superior stability compared to other brand available aminopropyl columns, as our newly developed \"Evolved Surface Silica\" is chemically bonded with aminopropyl group. Generally, aminopropyl columns are used for applications that are hard to be separated in a reversed phase mode, such as simultaneous analysis of sugars or vitamin E. However, the shift in retention time has been an issue for a long time. Inertsil NH2 delivers highly reliable reproducibility and stability with accurate qualitative and quantitative results. Furthermore, aminopropyl columns generally cannot be washed by weakly acidic eluent, however Inertsil NH2 was improved and it can be washed by weakly acidic eluent.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: 3 Series High Purity Silica Gel\u003c\/li\u003e\n\u003cli\u003eParticle size: 5 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 450 m2\/g\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm)\u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Aminopropyl\u003c\/li\u003e\n\u003cli\u003eEnd-capping: None\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 8.0 %\u003c\/li\u003e\n\u003cli\u003eUSP Code: L8\u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911900451,"sku":"GLS502005545","price":630.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002816_inertsil-nh2_03935779-9733-4c82-8555-ba12452db5c6.png?v=1753023300"},{"product_id":"inertsil-nh2-analytical-column-250-x-4-6-mm-5-um","title":"Inertsil NH2 Analytical Column, 250 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil NH2 amino column shows far superior stability compared to other brand available aminopropyl columns, as our newly developed \"Evolved Surface Silica\" is chemically bonded with aminopropyl group. Generally, aminopropyl columns are used for applications that are hard to be separated in a reversed phase mode, such as simultaneous analysis of sugars or vitamin E. However, the shift in retention time has been an issue for a long time. Inertsil NH2 amino column delivers highly reliable reproducibility and stability with accurate qualitative and quantitative results. Furthermore, aminopropyl columns generally cannot be washed by weakly acidic eluent, however Inertsil NH2 amino column was improved and it can be washed by weakly acidic eluent.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material : 3 Series High Purity Silica Gel\u003c\/li\u003e\n\u003cli\u003eParticle Size : 5 μm\u003c\/li\u003e\n\u003cli\u003eSurface Area : 450 m2\/g\u003c\/li\u003e\n\u003cli\u003ePore Size : 100 Å (10 nm)\u003c\/li\u003e\n\u003cli\u003ePore Volume : 1.05 mL\/g\u003c\/li\u003e\n\u003cli\u003eFunctional Group : Aminopropyl\u003c\/li\u003e\n\u003cli\u003eEnd-capping : No\u003c\/li\u003e\n\u003cli\u003eCarbon Loading : 8 %\u003c\/li\u003e\n\u003cli\u003eUSP Code : L8\u003c\/li\u003e\n\u003cli\u003epH Range : 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911933219,"sku":"GLS502005546","price":729.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002816_inertsil-nh2_68628aa2-db3e-4103-81e2-79d89ca8398d.png?v=1753023304"},{"product_id":"inertsil-wp300-c8-analytical-column-150-x-4-6-mm-5-um","title":"Inertsil WP300 C8 Analytical Column, 150 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertsil WP300 C8 (wide pore size of 300 Å) columns bring the same legendary performance of Inertsil's narrow-pore HPLC products to columns designed specifically for the reproducible rapid separations of proteins and peptides. Inertsil WP300 C8 delivers rapid analysis with sharper peaks compared to Inertsil WP300 C18.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: WP300 Series High Purity Silica Gel \u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm \u003c\/li\u003e\n\u003cli\u003eSurface Area: 150 m2\/g \u003c\/li\u003e\n\u003cli\u003ePore Size: 300 Å (30 nm) \u003c\/li\u003e\n\u003cli\u003ePore Volume: 1.05 mL\/g \u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octyl \u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 4.0 % \u003c\/li\u003e\n\u003cli\u003eUSP Code: L7 \u003c\/li\u003e\n\u003cli\u003epH Range: 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613911998755,"sku":"GLS502005744","price":839.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002804_inertsil-wp300-c8_550.png?v=1753023308"},{"product_id":"inertsil-cx-analytical-column-250-x-4-6-mm-5-um","title":"Inertsil CX Analytical Column, 250 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eThe Inertsil CX Cation Exchange HPLC Column has benzenesulfonyl groups bonded to silica gel by an alkyl chain. The sulfonyl groups at the end of the structure offer cationic functions required for the cation exchange chromatography. It is mainly used for analyses of basic compounds. Inertsil CX is manufactured under strict quality control in order to offer excellent batch to batch reproducibility as the same as Inertsil AX. Inertsil CX Cation Exchange Column has high ion exchange capacity and provides high retentivity and selectivity. Therefore, it is also suited for analyzing amino acids and nucleobases.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material : 3 Series High Purity Silica Gel\u003c\/li\u003e\n\u003cli\u003eParticle Size : 5 μm\u003c\/li\u003e\n\u003cli\u003eSurface Area : 450 m2\/g\u003c\/li\u003e\n\u003cli\u003ePore Size : 100 Å (10 nm)\u003c\/li\u003e\n\u003cli\u003ePore Volume : 1.05 mL\/g\u003c\/li\u003e\n\u003cli\u003eFunctional Group : Benzensulfonyl\u003c\/li\u003e\n\u003cli\u003eEnd-capping : No\u003c\/li\u003e\n\u003cli\u003eCarbon Loading : 14 %\u003c\/li\u003e\n\u003cli\u003eCation Exchange Capacity : 0.5 meq\/g\u003c\/li\u003e\n\u003cli\u003eUSP Code : L9\u003c\/li\u003e\n\u003cli\u003epH Range : 2 - 7.5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912031523,"sku":"GLS502007146","price":854.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/0002827_inertsil-cx-cation-exchange-hplc-columns.png?v=1753023312"},{"product_id":"inertsustain-c18-analytical-column-150-x-4-0-mm-5-um","title":"InertSustain C18 Analytical Column, 150 x 4.0 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eGenerally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C18 employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties.\r\u003c\/p\u003e\u003cp class=\"richp\"\u003eInertSustain C18 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.\r\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel \r\u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g \r\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \r\u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g \r\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \r\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \r\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 14.0 % \r\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \r\u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912064291,"sku":"GLS502007335","price":576.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl.jpg?v=1764358275"},{"product_id":"inertsustain-c18-analytical-column-150-x-4-6-mm-5-um","title":"InertSustain C18 Analytical Column, 150 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eGenerally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C18 employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties.\n\u003c\/p\u003e\u003cp class=\"richp\"\u003eInertSustain C18 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel \n\u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm \n\u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g \n\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \n\u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g \n\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \n\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \n\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 14.0 % \n\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \n\u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912129827,"sku":"GLS502007345","price":576.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_11704694-8587-4343-a8b1-9cc2e1dc1ba8.jpg?v=1764358288"},{"product_id":"inertsustain-c18-analytical-column-250-x-4-6-mm-5-um","title":"InertSustain C18 Analytical Column, 250 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eGenerally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C18 employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties.\n\u003c\/p\u003e\u003cp class=\"richp\"\u003eInertSustain C18 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel \n\u003c\/li\u003e\n\u003cli\u003eParticle Size: 5 µm \n\u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g \n\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \n\u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g \n\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \n\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \n\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 14.0 % \n\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \n\u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912228131,"sku":"GLS502007346","price":666.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_24351bf2-446a-45e8-ae69-2b4b88965eb6.jpg?v=1764358292"},{"product_id":"inertsustain-c18-analytical-column-150-x-3-0-mm-3-um","title":"InertSustain C18 Analytical Column, 150 x 3.0 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eGenerally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C18 employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties.\u003c\/p\u003e\u003cp class=\"richp\"\u003eInertSustain C18 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel \u003c\/li\u003e\n\u003cli\u003eParticle Size: 3 µm \u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g \u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g \u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 14.0 % \u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912326435,"sku":"GLS502007425","price":717.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_1a0164ac-640f-442f-bbee-a955e041a880.jpg?v=1764358296"},{"product_id":"inertsustain-c18-analytical-column-100-x-4-6-mm-3-um","title":"InertSustain C18 Analytical Column, 100 x 4.6 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eGenerally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C18 employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties.\r\u003c\/p\u003e\u003cp class=\"richp\"\u003eInertSustain C18 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.\r\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel \r\u003c\/li\u003e\n\u003cli\u003eParticle Size: 2 µm, 3 µm, 3.5 µm, 5 µm, 10 µm \r\u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g \r\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \r\u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g \r\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \r\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \r\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 14.0 % \r\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \r\u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912424739,"sku":"GLS502007444","price":620.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_0320f5dc-4a4e-4ad9-998e-e90a43270635.jpg?v=1764358300"},{"product_id":"inertsustain-c18-analytical-column-150-x-4-6-mm-3-um","title":"InertSustain C18 Analytical Column, 150 x 4.6 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eGenerally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C18 employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties.\n\u003c\/p\u003e\u003cp class=\"richp\"\u003eInertSustain C18 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel \n\u003c\/li\u003e\n\u003cli\u003eParticle Size: 3 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g \n\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \n\u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g \n\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl \n\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \n\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 14.0 % \n\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1 \n\u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912523043,"sku":"GLS502007445","price":717.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_b7b88079-c392-4685-a244-bb3594c3dba3.jpg?v=1764358305"},{"product_id":"inertsustain-c18-analytical-column-250-x-4-6-mm-3-um","title":"InertSustain C18 Analytical Column, 250 x 4.6 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eGenerally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C18 employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties.\r\u003c\/p\u003e\u003cp class=\"richp\"\u003eInertSustain C18 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.\r\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel\r\u003c\/li\u003e\n\u003cli\u003eParticle Size: 3 µm\r\u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g\r\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm)\r\u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g\r\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl\r\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes\r\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 14.0 %\r\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1\r\u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912621347,"sku":"GLS502007446","price":825.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_de1f0d75-b830-4fc6-bbde-d747e64011f2.jpg?v=1764358309"},{"product_id":"inertsustain-c18-analytical-column-125-x-4-6-mm-3-um","title":"InertSustain C18 Analytical Column, 125 x 4.6 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eGenerally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C18 employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties.\r\u003c\/p\u003e\u003cp class=\"richp\"\u003eInertSustain C18 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.\r\u003c\/p\u003e\u003cp class=\"richp\"\u003e\r\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel\r\u003c\/li\u003e\n\u003cli\u003eParticle Size: 3 µm\u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g\r\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm)\r\u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g\r\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octadecyl\r\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes\r\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 14.0 %\r\u003c\/li\u003e\n\u003cli\u003eUSP Code: L1\r\u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613912719651,"sku":"GLS502007447","price":717.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_0bca62ca-79dd-4fcc-bb9f-88afa79ffa5c.jpg?v=1764358313"},{"product_id":"inertsustain-c8-analytical-column-150-x-4-6-mm-5-um","title":"InertSustain C8 Analytical Column, 150 x 4.6 mm, 5 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertSustain C8 is an octyl group (C8) bonded column delivering the same extreme inertness to any type of compounds just like InertSustain C18, which enables rapid analysis of highly hydrophobic compounds delivering symmetric peaks at a wide range of pH.\u003c\/p\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613913112867,"sku":"GLS502016027","price":576.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_d0f7ed96-d9ce-4ab6-952f-53a0396e9237.jpg?v=1764358331"},{"product_id":"inertsustain-c8-analytical-column-50-x-4-6-mm-3-um","title":"InertSustain C8 Analytical Column, 50 x 4.6 mm, 3 µm, Non-returnable, Non-refundable","description":"\u003cp class=\"richp\"\u003eInertSustain C8 is an octyl group (C8) bonded column delivering the same extreme inertness to any type of compounds just like InertSustain C18, which enables rapid analysis of highly hydrophobic compounds delivering symmetric peaks at a wide range of pH.\r\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBase Material: High Purity ES Silica Gel \r\u003c\/li\u003e\n\u003cli\u003eParticle Size: 3 µm \r\u003c\/li\u003e\n\u003cli\u003eSurface Area: 350 m2\/g \r\u003c\/li\u003e\n\u003cli\u003ePore Size: 100 Å (10 nm) \r\u003c\/li\u003e\n\u003cli\u003ePore Volume: 0.85 mL\/g \r\u003c\/li\u003e\n\u003cli\u003eFunctional Group: Octyl \r\u003c\/li\u003e\n\u003cli\u003eEnd-capping: Yes \r\u003c\/li\u003e\n\u003cli\u003eCarbon Loading: 8.0 % \r\u003c\/li\u003e\n\u003cli\u003eUSP Code: L7 \r\u003c\/li\u003e\n\u003cli\u003epH Range: 1 - 10\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GL Sciences","offers":[{"title":"Default Title","offer_id":53613913145635,"sku":"GLS502016154","price":555.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/GL_Sciences_InertSustain_HPLC_Column_2048x2048pxl_06782a30-5706-428d-94bc-46824060bb0e.jpg?v=1764358335"}],"url":"https:\/\/chromspec.com\/collections\/6077-analytical.oembed?page=364","provider":"Chromatographic Specialties Inc.","version":"1.0","type":"link"}