{"title":"RMX GC Columns","description":null,"products":[{"product_id":"rmx-5sil-ms-capillary-column-15-m-0-25-mm-id-0-25-µm","title":"RMX-5Sil MS Capillary Column, 15 m x 0.25 mm ID, 0.25 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.25 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli\u003eLength:  15 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674658165027,"sku":"RK17320","price":758.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl.jpg?v=1769107202"},{"product_id":"rmx-5sil-ms-capillary-column-15-m-x-0-25-mm-id-0-25-µm-with-5-m-integra-guard","title":"RMX-5Sil MS Capillary Column, 15 m x 0.25 mm ID, 0.25 µm, with 5 m Integra-Guard","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.25 µm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eLength:  15 m\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eModification:  with 5m Integra-Guard Column\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674658492707,"sku":"RK17320124","price":889.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_5m_integra_guard_2048x2048pxl.jpg?v=1769116966"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-0-25-mm-id-0-25-µm","title":"RMX-5Sil MS Capillary Column, 30 m x 0.25 mm ID, 0.25 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.25 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674658623779,"sku":"RK17323","price":1349.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_ac10cf0a-63dc-4c49-92cf-db8493027dce.jpg?v=1769107213"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-x-0-25-mm-id-0-25-µm-with-5-m-integra-guard","title":"RMX-5Sil MS Capillary Column, 30 m x 0.25 mm ID, 0.25 µm, with 5 m Integra-Guard","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.25 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eModification:  with 5m Integra-Guard Column\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674658820387,"sku":"RK17323124","price":1481.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_5m_integra_guard_2048x2048pxl_0a0fb314-1837-49b1-b68b-11c513e033e7.jpg?v=1769116974"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-x-0-25-mm-id-0-25-µm-with-5-m-integra-guard-integra-transfer-line","title":"RMX-5Sil MS Capillary Column, 30 m x 0.25 mm ID, 0.25 µm, with 5 m Integra-Guard \u0026 Integra-Transfer Line","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.25 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli\u003eLength:  30 m\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eModification:  with 5m Integra-Guard Column \u0026amp; Integra-Transfer Line\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674658918691,"sku":"RK17323124177","price":1612.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_5m_integra_guard_and_transfer_line2048x2048pxl.jpg?v=1769116979"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-x-0-25-mm-id-0-25-µm-with-integra-transfer-line","title":"RMX-5Sil MS Capillary Column, 30 m x 0.25 mm ID, 0.25 µm, with Integra Transfer Line","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.25 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli\u003eLength:  30 m\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eModification:  with Integra Transfer Line\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674659082531,"sku":"RK17323177","price":1481.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_integra_transfer_line2048x2048pxl.jpg?v=1769116984"},{"product_id":"rmx-5sil-ms-agilent-precision-liner-kit","title":"RMX-5Sil MS Precision Liner Kit for Agilent GCs","description":"\u003cp class=\"richp\"\u003ePair RMX GC columns with Topaz inlet liners to maximize sensitivity for a wide range of problematic active compounds, including acid, bases, alcohols, and more. By creating an exceptionally inert sample flow path, you can confidently quantitate at trace levels and boost productivity by meeting stringent data quality requirements longer.\u003c\/p\u003e\u003cp class=\"richp\" sugg=\"true\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximize trace-level sensitivity with kits that combine the next-generation inertness of RMX columns and Topaz inlet liners to give you a truly inert sample flow path and more confidence in your analytical data.\u003c\/li\u003e\n\u003cli\u003eRMX columns—featuring TriMax deactivation technology—deliver maximum inertness, sensitivity, and durability for demanding applications that include active compounds, such as semivolatiles analysis.\u003c\/li\u003e\n\u003cli\u003eChoose from single-taper and Precision-style Topaz inlet liners, both contain wool and are thoroughly passivated, minimizing analyte breakdown in the inlet.\u003c\/li\u003e\n\u003cli\u003eGet the convenience of a manufacturer-specific inlet liner and our most popular RMX-5Sil MS column format (30 m, 0.25 mm ID, 0.25 µm) in one easy order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProduct Name:  RMX-5Sil MS Precision Liner Kit for Agilent GCs\u003c\/li\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eIncludes:  30 m, 0.25 mm ID, 0.25 µm RMX-5Sil MS column (cat.# RK17323); and Topaz Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, with Quartz Wool, Premium Deactivation (cat.# RK23305, 5-pk)\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674659311907,"sku":"RK17323AG01","price":1565.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_column_with_precision_liner_5pk_2048x2048pxl.jpg?v=1769116988"},{"product_id":"rmx-5sil-ms-agilent-single-taper-liner-kit","title":"RMX-5Sil MS Single Taper Liner Kit for Agilent GCs","description":"\u003cp class=\"richp\"\u003ePair RMX GC columns with Topaz inlet liners to maximize sensitivity for a wide range of problematic active compounds, including acid, bases, alcohols, and more. By creating an exceptionally inert sample flow path, you can confidently quantitate at trace levels and boost productivity by meeting stringent data quality requirements longer.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximize trace-level sensitivity with kits that combine the next-generation inertness of RMX columns and Topaz inlet liners to give you a truly inert sample flow path and more confidence in your analytical data.\u003c\/li\u003e\n\u003cli\u003eRMX columns—featuring TriMax deactivation technology—deliver maximum inertness, sensitivity, and durability for demanding applications that include active compounds, such as semivolatiles analysis.\u003c\/li\u003e\n\u003cli\u003eChoose from single-taper and Precision-style Topaz inlet liners, both contain wool and are thoroughly passivated, minimizing analyte breakdown in the inlet.\u003c\/li\u003e\n\u003cli\u003eGet the convenience of a manufacturer-specific inlet liner and our most popular RMX-5Sil MS column format (30 m, 0.25 mm ID, 0.25 µm) in one easy order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProduct Name:  RMX-5Sil MS Single Taper Liner Kit for Agilent GCs\u003c\/li\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eIncludes:  30 m, 0.25 mm ID, 0.25 µm RMX-5Sil MS column (cat.# RK17323); and Topaz Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation (cat.# RK23303, 5-pk)\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674659508515,"sku":"RK17323AG02","price":1565.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_17323-AG02_rmx_column_with_single_taper_liner_5pk_2048x2048pxl.jpg?v=1769119300"},{"product_id":"rmx-5sil-ms-perkinelmer-precision-liner-kit","title":"RMX-5Sil MS Precision Liner Kit for PerkinElmer GCs","description":"\u003cp class=\"richp\"\u003ePair RMX GC columns with Topaz inlet liners to maximize sensitivity for a wide range of problematic active compounds, including acid, bases, alcohols, and more. By creating an exceptionally inert sample flow path, you can confidently quantitate at trace levels and boost productivity by meeting stringent data quality requirements longer.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximize trace-level sensitivity with kits that combine the next-generation inertness of RMX columns and Topaz inlet liners to give you a truly inert sample flow path and more confidence in your analytical data.\u003c\/li\u003e\n\u003cli\u003eRMX columns—featuring TriMax deactivation technology—deliver maximum inertness, sensitivity, and durability for demanding applications that include active compounds, such as semivolatiles analysis.\u003c\/li\u003e\n\u003cli\u003eChoose from single-taper and Precision-style Topaz inlet liners, both contain wool and are thoroughly passivated, minimizing analyte breakdown in the inlet.\u003c\/li\u003e\n\u003cli\u003eGet the convenience of a manufacturer-specific inlet liner and our most popular RMX-5Sil MS column format (30 m, 0.25 mm ID, 0.25 µm) in one easy order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProduct Name:  RMX-5Sil MS Precision Liner Kit for PerkinElmer GCs\u003c\/li\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eIncludes:  30 m, 0.25 mm ID, 0.25 µm RMX-5Sil MS column (cat.# RK17323); and Topaz Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for PerkinElmer Clarus 590\/690 and GC2400 GCs, w\/Quartz Wool, Premium Deactivation (cat.# RK23799, 5-pk)\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674659803427,"sku":"RK17323PE01","price":1565.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_column_with_precision_liner_5pk_2048x2048pxl_19a481f7-2fc5-4545-a72a-d4c1d7ee9982.jpg?v=1769116997"},{"product_id":"rmx-5sil-ms-perkinelmer-single-taper-liner-kit","title":"RMX-5Sil MS Single Taper Liner Kit for PerkinElmer GCs","description":"\u003cp class=\"richp\"\u003ePair RMX GC columns with Topaz inlet liners to maximize sensitivity for a wide range of problematic active compounds, including acid, bases, alcohols, and more. By creating an exceptionally inert sample flow path, you can confidently quantitate at trace levels and boost productivity by meeting stringent data quality requirements longer.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximize trace-level sensitivity with kits that combine the next-generation inertness of RMX columns and Topaz inlet liners to give you a truly inert sample flow path and more confidence in your analytical data.\u003c\/li\u003e\n\u003cli\u003eRMX columns—featuring TriMax deactivation technology—deliver maximum inertness, sensitivity, and durability for demanding applications that include active compounds, such as semivolatiles analysis.\u003c\/li\u003e\n\u003cli\u003eChoose from single-taper and Precision-style Topaz inlet liners, both contain wool and are thoroughly passivated, minimizing analyte breakdown in the inlet.\u003c\/li\u003e\n\u003cli\u003eGet the convenience of a manufacturer-specific inlet liner and our most popular RMX-5Sil MS column format (30 m, 0.25 mm ID, 0.25 µm) in one easy order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProduct Name:  RMX-5Sil MS Single Taper Liner Kit for PerkinElmer GCs\u003c\/li\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eIncludes:  30 m, 0.25 mm ID, 0.25 µm RMX-5Sil MS column (cat.# RK17323); and Topaz Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for PerkinElmer Clarus 590\/690 and GC2400 GCs, with Quartz Wool, Premium Deactivation (cat.# RK23800, 5-pk)\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674659967267,"sku":"RK17323PE02","price":1565.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_17323-AG02_rmx_column_with_single_taper_liner_5pk_2048x2048pxl_5c51a203-384a-4d34-b0cd-04d772e07491.jpg?v=1769119304"},{"product_id":"rmx-5sil-ms-shimadzu-precision-liner-kit","title":"RMX-5Sil MS Precision Liner Kit for Shimadzu GCs","description":"\u003cp class=\"richp\"\u003ePair RMX GC columns with Topaz inlet liners to maximize sensitivity for a wide range of problematic active compounds, including acid, bases, alcohols, and more. By creating an exceptionally inert sample flow path, you can confidently quantitate at trace levels and boost productivity by meeting stringent data quality requirements longer.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximize trace-level sensitivity with kits that combine the next-generation inertness of RMX columns and Topaz inlet liners to give you a truly inert sample flow path and more confidence in your analytical data.\u003c\/li\u003e\n\u003cli\u003eRMX columns—featuring TriMax deactivation technology—deliver maximum inertness, sensitivity, and durability for demanding applications that include active compounds, such as semivolatiles analysis.\u003c\/li\u003e\n\u003cli\u003eChoose from single-taper and Precision-style Topaz inlet liners, both contain wool and are thoroughly passivated, minimizing analyte breakdown in the inlet.\u003c\/li\u003e\n\u003cli\u003eGet the convenience of a manufacturer-specific inlet liner and our most popular RMX-5Sil MS column format (30 m, 0.25 mm ID, 0.25 µm) in one easy order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProduct Name:  RMX-5Sil MS Precision Liner Kit for Shimadzu GCs\u003c\/li\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eIncludes:  30 m, 0.25 mm ID, 0.25 µm RMX-5Sil MS column (cat.# RK17323); and Topaz Precision Inlet Liner, 3.5 mm x 5.0 x 95, for Shimadzu 17A, 2010, 2014, and 2030 GCs, w\/Quartz Wool, Premium Deactivation (cat.# RK23320, 5-pk)\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674660131107,"sku":"RK17323SH01","price":1565.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_column_with_precision_liner_5pk_2048x2048pxl_22f79706-c240-4cf0-abcd-c6f83c17dacf.jpg?v=1769117006"},{"product_id":"rmx-5sil-ms-shimadzu-single-taper-liner-kit","title":"RMX-5Sil MS Single Taper Liner Kit for Shimadzu GCs","description":"\u003cp class=\"richp\"\u003ePair RMX GC columns with Topaz inlet liners to maximize sensitivity for a wide range of problematic active compounds, including acid, bases, alcohols, and more. By creating an exceptionally inert sample flow path, you can confidently quantitate at trace levels and boost productivity by meeting stringent data quality requirements longer.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximize trace-level sensitivity with kits that combine the next-generation inertness of RMX columns and Topaz inlet liners to give you a truly inert sample flow path and more confidence in your analytical data.\u003c\/li\u003e\n\u003cli\u003eRMX columns—featuring TriMax deactivation technology—deliver maximum inertness, sensitivity, and durability for demanding applications that include active compounds, such as semivolatiles analysis.\u003c\/li\u003e\n\u003cli\u003eChoose from single-taper and Precision-style Topaz inlet liners, both contain wool and are thoroughly passivated, minimizing analyte breakdown in the inlet.\u003c\/li\u003e\n\u003cli\u003eGet the convenience of a manufacturer-specific inlet liner and our most popular RMX-5Sil MS column format (30 m, 0.25 mm ID, 0.25 µm) in one easy order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProduct Name:  RMX-5Sil MS Single Taper Liner Kit for Shimadzu GCs\u003c\/li\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eIncludes:  30 m, 0.25 mm ID, 0.25 µm RMX-5Sil MS column (cat.# RK17323); and Topaz, Single Taper Inlet Liner, 3.5 mm x 5.0 x 95, for Shimadzu 17A, 2010, 2014, and 2030 GCs, with Quartz Wool Near Bottom, Premium Deactivation (cat.# RK23336, 5-pk)\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674660360483,"sku":"RK17323SH02","price":1722.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_column_with_single_taper_liner_5pk_17323-SH02_2048x2048pxl.jpg?v=1769119308"},{"product_id":"rmx-5sil-ms-thermo-precision-liner-kit","title":"RMX-5Sil MS Precision Liner Kit for Thermo GCs","description":"\u003cp class=\"richp\"\u003ePair RMX GC columns with Topaz inlet liners to maximize sensitivity for a wide range of problematic active compounds, including acid, bases, alcohols, and more. By creating an exceptionally inert sample flow path, you can confidently quantitate at trace levels and boost productivity by meeting stringent data quality requirements longer.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximize trace-level sensitivity with kits that combine the next-generation inertness of RMX columns and Topaz inlet liners to give you a truly inert sample flow path and more confidence in your analytical data.\u003c\/li\u003e\n\u003cli\u003eRMX columns—featuring TriMax deactivation technology—deliver maximum inertness, sensitivity, and durability for demanding applications that include active compounds, such as semivolatiles analysis.\u003c\/li\u003e\n\u003cli\u003eChoose from single-taper and Precision-style Topaz inlet liners, both contain wool and are thoroughly passivated, minimizing analyte breakdown in the inlet.\u003c\/li\u003e\n\u003cli\u003eGet the convenience of a manufacturer-specific inlet liner and our most popular RMX-5Sil MS column format (30 m, 0.25 mm ID, 0.25 µm) in one easy order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProduct Name:  RMX-5Sil MS Precision Liner Kit for Thermo GCs\u003c\/li\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eIncludes:  30 m, 0.25 mm ID, 0.25 µm RMX-5Sil MS column (cat.# RK17323); and Topaz Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Thermo TRACE 1300\/1310, 1600\/1610 GCs w\/SSL Inlets, Quartz Wool, Premium Deactivation (cat.# RK23267, 5-pk)\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674660458787,"sku":"RK17323TH01","price":1565.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_column_with_precision_liner_5pk_2048x2048pxl_4420e1ef-8992-432a-8d73-e197d1fc7091.jpg?v=1769117014"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-0-32-mm-id-0-25-µm","title":"RMX-5Sil MS Capillary Column, 30 m x 0.32 mm ID, 0.25 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.25 µm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eInner Diameter (ID):  0.32 mm\u003c\/li\u003e\n\u003cli\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674660524323,"sku":"RK17324","price":1457.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_8f16c174-da29-45b3-a916-d8b6bfe0c079.jpg?v=1769107264"},{"product_id":"rmx-5sil-ms-capillary-column-60-m-x-0-25-mm-id-0-25-µm","title":"RMX-5Sil MS Capillary Column, 60 m x 0.25 mm ID, 0.25 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.25 µm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli\u003eLength:  60 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674660753699,"sku":"RK17326","price":2298.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_3179a6d3-301a-4604-a92f-94f26a1550bc.jpg?v=1769107269"},{"product_id":"rmx-5sil-ms-capillary-column-15-m-x-0-25-mm-id-0-50-µm","title":"RMX-5Sil MS Capillary Column, 15 m x 0.25 mm ID, 0.50 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003edf (Film Thickness):  0.50 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eLength:  15 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674660852003,"sku":"RK17335","price":889.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_9a762c79-8da1-4014-b7bc-563c96dd7ee1.jpg?v=1769107275"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-x-0-25-mm-id-0-50-µm","title":"RMX-5Sil MS Capillary Column, 30 m x 0.25 mm ID, 0.50 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.50 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674661245219,"sku":"RK17338","price":1349.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_efe7cccc-29e2-45dd-b697-026fbef98c2a.jpg?v=1769107280"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-x-0-25-mm-id-0-50-µm-with-5-m-integra-guard","title":"RMX-5Sil MS Capillary Column, 30 m x 0.25 mm ID, 0.50 µm, with 5 m Integra-Guard","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003edf (Film Thickness):  0.50 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eModification:  with 5m Integra-Guard Column\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674661376291,"sku":"RK17338124","price":1481.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_5m_integra_guard_2048x2048pxl_171823ac-a0de-449c-9ec9-d96817f8f923.jpg?v=1769117039"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-x-0-32-mm-id-0-50-µm","title":"RMX-5Sil MS Capillary Column, 30 m x 0.32 mm ID, 0.50 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  0.50 µm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eInner Diameter (ID):  0.32 mm\u003c\/li\u003e\n\u003cli\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674661703971,"sku":"RK17339","price":1457.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_89a6a70b-b9c2-4954-97f6-c467cb29a6c2.jpg?v=1769107291"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-x-0-25-mm-id-1-00-µm","title":"RMX-5Sil MS Capillary Column, 30 m x 0.25 mm ID, 1.00 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003edf (Film Thickness):  1.00 µm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eInner Diameter (ID):  0.25 mm\u003c\/li\u003e\n\u003cli\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674661835043,"sku":"RK17353","price":1349.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_633942c4-0857-4ebb-90ea-996dc836ef39.jpg?v=1769107297"},{"product_id":"rmx-5sil-ms-capillary-column-30-m-x-0-32-mm-id-1-00-µm","title":"RMX-5Sil MS Capillary Column, 30 m x 0.32 mm ID, 1.00 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli\u003edf (Film Thickness):  1.00 µm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eInner Diameter (ID):  0.32 mm\u003c\/li\u003e\n\u003cli\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674662031651,"sku":"RK17354","price":1457.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_c099744b-34eb-4da0-9d5c-6fcd13e7df65.jpg?v=1769107300"},{"product_id":"rmx-5sil-ms-capillary-column-20-m-x-0-18-mm-id-0-18-µm","title":"RMX-5Sil MS Capillary Column, 20 m x 0.18 mm ID, 0.18 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003edf (Film Thickness):  0.18 µm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eInner Diameter (ID):  0.18 mm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eLength:  20 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674662326563,"sku":"RK47302","price":1310.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_36281fa1-24f0-46eb-b742-bf6ca11710d6.jpg?v=1769107311"},{"product_id":"rmx-5sil-ms-capillary-column-20-m-x-0-18-mm-id-0-18-µm-with-5-m-integra-guard","title":"RMX-5Sil MS Capillary Column, 20 m x 0.18 mm ID, 0.18 µm, with 5 m Integra-Guard","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003edf (Film Thickness):  0.18 µm\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003eInner Diameter (ID):  0.18 mm\u003c\/li\u003e\n\u003cli\u003eLength:  30 m\u003c\/li\u003e\n\u003cli\u003eModification:  with 5m Integra-Guard Column\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674662490403,"sku":"RK47302135","price":1441.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_5m_integra_guard_2048x2048pxl_5038388e-cc6c-481c-afd5-1a1b68ca993f.jpg?v=1769180093"},{"product_id":"rmx-5sil-ms-capillary-column-20-m-x-0-18-mm-id-0-36-µm","title":"RMX-5Sil MS Capillary Column, 20 m x 0.18 mm ID, 0.36 µm","description":"\u003cp class=\"richp\"\u003eExperience extended column lifetime, achieve wider calibration ranges and lower levels of detection, and confidently quantitate problematic active analytes with RMX GC columns, featuring TriMax deactivation technology. TriMax deactivation delivers an exceptionally inert, contaminant-free surface, enabling RMX columns to provide trace-level detection, symmetrical peaks, and rugged performance that bounces back even after aggressive thermal cycles and heavy contamination. Empower your lab to boost productivity by meeting stringent data quality requirements longer, even for expanded analyte lists containing a wide range of extremely challenging compounds.\u003c\/p\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNext-generation TriMax deactivation creates a resilient stationary phase and exceptionally neutral sample flow path, delivering the stability needed for extended calibration intervals and more reliable data.\u003c\/li\u003e\n\u003cli\u003eMaximum inertness improves peak shape for problematic active compound classes, achieving lower detection limits and picogram-level sensitivity for confident quantification of a wide range of analytes.\u003c\/li\u003e\n\u003cli\u003eSuperior column performance supports method consolidation for increased productivity and scaled-down sample extraction volumes for reduced solvent use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eSimilar Phases:  Agilent DB-5Q, DB-5msUI, DB-UI 8270D • Phenomenex ZB-5ms PLUS, ZB-Semivolatiles\u003c\/li\u003e\n\u003cli sugg=\"true\"\u003edf (Film Thickness):  0.36 µm\u003c\/li\u003e\n\u003cli\u003eInner Diameter (ID):  0.18 mm\u003c\/li\u003e\n\u003cli\u003eLength:  20 m\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674662588707,"sku":"RK47311","price":1310.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_rmx_gc_column_with_box_2048x2048pxl_98493371-3f6d-4137-b425-3bbe7a10a01e.jpg?v=1769107319"},{"product_id":"rmx-5sil-ms-thermo-single-taper-liner-kit","title":"RMX-5Sil MS Single Taper Liner Kit for Thermo GCs","description":"\u003cp class=\"richp\"\u003ePair RMX GC columns with Topaz inlet liners to maximize sensitivity for a wide range of problematic active compounds, including acid, bases, alcohols, and more. By creating an exceptionally inert sample flow path, you can confidently quantitate at trace levels and boost productivity by meeting stringent data quality requirements longer.\u003c\/p\u003e\u003cdiv\u003e\u003cb\u003eFeatures \u0026amp; Benefits:\u003c\/b\u003e\u003c\/div\u003e\u003cul\u003e\n\u003cli\u003eMaximize trace-level sensitivity with kits that combine the next-generation inertness of RMX columns and Topaz inlet liners to give you a truly inert sample flow path and more confidence in your analytical data.\u003c\/li\u003e\n\u003cli\u003eRMX columns—featuring TriMax deactivation technology—deliver maximum inertness, sensitivity, and durability for demanding applications that include active compounds, such as semivolatiles analysis.\u003c\/li\u003e\n\u003cli\u003eChoose from single-taper and Precision-style Topaz inlet liners, both contain wool and are thoroughly passivated, minimizing analyte breakdown in the inlet.\u003c\/li\u003e\n\u003cli\u003eGet the convenience of a manufacturer-specific inlet liner and our most popular RMX-5Sil MS column format (30 m, 0.25 mm ID, 0.25 µm) in one easy order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"richp\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProduct Name:  RMX-5Sil MS Single Taper Liner Kit for Thermo GCs\u003c\/li\u003e\n\u003cli\u003eStationary Phase:  RMX-5Sil MS\u003c\/li\u003e\n\u003cli\u003eIncludes:  30 m, 0.25 mm ID, 0.25 µm RMX-5Sil MS column (cat.# RK17323); and Topaz Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Thermo TRACE 1300\/1310, 1600\/1610 GCs w\/SSL inlets, w\/Quartz Wool, Premium Deactivation (cat.# RK23447, 5-pk)\u003c\/li\u003e\n\u003cli\u003eTemp Limits:  -60 to 340\/350 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Restek","offers":[{"title":"Default Title","offer_id":54674670551331,"sku":"RK17323TH02","price":1565.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/3870\/8003\/files\/restek_17323-AG02_rmx_column_with_single_taper_liner_5pk_2048x2048pxl_b01f4738-4b45-473c-a37b-777954de9dbd.jpg?v=1769119312"}],"url":"https:\/\/chromspec.com\/collections\/rmx-gc-columns.oembed","provider":"Chromatographic Specialties Inc.","version":"1.0","type":"link"}