SilTite® Metal Ferrules


Having Problems With 100% Graphite and Composite Ferrules?

Trajan Logo

Trajan has developed ferrules specifically to overcome the problems associated with the use of 100% graphite and composite ferrules.

SilTite ferrules form a strong and permanent airtight seal around the capillary column and have a temperature limit well above the temperature capacity of the injector, MS interface or GC oven. The metal SilTite ferrule together with the metal
nut have the same coefficient of thermal expansion. The ferrule and nut expand and contract at the same rate 
eliminating any chance of annoying leaks. The nut does not need to be re-tightened after initial temperature cycles.

  • Strong seal on capillary columns - reduced air background.
  • No contamination - cleaner spectra.
  • Leak free - nut does not need re-tightening after initial temperature cycles.

Recommended applications: MS interfaces. Kits available for Agilent, PerkinElmer, Shimadzu, Thermo Scientific, and Varian/Bruker GC-MS systems.

Product Number
Description
For use on Agilent
SGE073270 SilTite metal - initial installation for use on Split/splitless injectors (starter kit).
For use with 0.10-0.25 mm ID columns (10 ferrules, 2 nuts, inlet base seals)
SGE073271 SilTite metal - initial installation for use on Split/splitless injectors (starter kit).
For use with 0.32 mm ID columns (10 ferrules, 2 nuts, inlet base seals)
SGE073272 SilTite metal - initial installation for use on Split/splitless injectors (starter kit).
For use with 0.45-0.53 mm ID columns (10 ferrules, 2 nuts, inlet base seals)
SGE073273 SilTite metal - initial installation for use on Split/splitless injectors (starter kit).
For use with 1/32" ID columns (10 ferrules, 2 nuts, inlet base seals)
SGE073400 SilTite base seals
SGE073401 SilTite base seals
SGE073200 SilTite metal - initial installation for GCMS interface connection for use with 0.10-0.25 mm ID columns (10 ferrules, 2 nuts)
SGE073201 SilTite metal - initial installation for GCMS interface connection for use with 0.32 mm ID columns (10 ferrules, 2 nuts)
SGE073202 SilTite metal - initial installation for GCMS interface connection for use with 0.45-0.53 mm ID columns, PK10 (10 ferrules, 2 nuts)
SGE073220 SilTite ferrules for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interface for use with 0.10-0.25 mm ID columns, PK10
SGE073221 SilTite ferrules for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interface for use with 0.32 mm ID columns, PK10
SGE073222 SilTite ferrules for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interfacefor for use with 0.45-0.53 mm ID columns, PK10
SGE073219 SilTite ferrules for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interface for use with 1/32" columns, PK10
SGE073224 Replacement SilTite metal nuts for Agilent GCMS interface connections, PK5
SGE073226 Replacement SilTite metal nuts for Agilent GC split/splitless injector, PK 5
For use on Varian/Bruker interface connections
SGE073300 SilTite metal - initial installation 0.10-0.25mm ID columns for Varian/Bruker GCMS interface connections (10 ferrules, 2 nuts)
SGE073301 SilTite metal - initial installation 0.32 mm ID columns for Varian/Bruker GCMS interface connections (10 ferrules, 2 nuts)
SGE073302 SilTite metal - initial installation 0.45-0.53 mm ID columns for Varian/Bruker GCMS interface connections (10 ferrules, 2 nuts)
SGE073231 SilTite metal nuts for Varian/Bruker GCMS interface connections, PK5
For use on Shimadzu
SGE073204 SilTite metal - initial installation for Shimadzu QP5000/5050 standard MS interface for use with 0.10-0.25 mm ID columns (10 ferrules, 2 nuts)
SGE073205 SilTite metal - initial installation for Shimadzu QP5000/5050 standard MS interface for use with 0.32 mm ID columns (10 ferrules, 2 nuts)
SGE073233 SilTite metal nuts - for use with QP5000/5050 standard MS interface, PK5
SGE073227 SilTite ferrules for Shimadzu GC-2014, GC-2010, GC-17A and GC-14A detector/injectors, and QP5000/5050 standard MS interface
(not for MS interfaces or QP2010 injector) for use with 0.10-0.25 mm ID columns, PK10
SGE073228 SilTite ferrules for Shimadzu GC-2014, GC-2010, GC-17A and GC-14A detector/injectors, and QP5000/5050 standard MS interface
(not for MS interfaces or QP2010 injector) for use with 0.32 mm ID columns, PK10
SGE073229 SilTite ferrules for Shimadzu GC-2014, GC-2010, GC-17A and GC-14A detector/injectors, and QP5000/5050 standard MS interface
(not for MS interfaces or QP2010 injector) for use with 0.45-0.53 mm ID columns, PK10
SGE073350 SilTite metal - initial installation for Shimadzu GC-2014, GC-2010, GC-17A and GC-14A detector/injectors, and QP5000/5050 standard MS interface
(not for MS interfaces or QP2010 injector) for 0.10-0.25 mm ID columns (10 ferrules, 2 nuts)
SGE073351 SilTite metal - initial installation for Shimadzu GC-2014, GC-2010, GC-17A and GC-14A detector/injectors, and QP5000/5050 standard MS interface
(not for MS interfaces or QP2010 injector) for 0.32 mm ID columns (10 ferrules, 2 nuts)
SGE073352 SilTite metal - initial installation for Shimadzu GC-2014, GC-2010, GC-17A and GC-14A detector/injectors, and QP5000/5050 standard MS interface
(not for MS interfaces or QP2010 injector) for 0.45-0.53 mm ID columns (10 ferrules, 2 nuts)
SGE073232 SilTite metal nuts, slotted, for Shimadzu GC-2014, GC-2010, GC-17A and GC-14A detector/injectors, and QP5000/5050 standard MS interface
(not for MS interfaces or QP2010 injector), PK5
For use on Thermo Scientific interface connections
SGE073200 SilTite metal - initial installation for GCMS interface connection for use with 0.10-0.25 mm ID columns (10 ferrules, 2 nuts)
SGE073201 SilTite metal - initial installation for GCMS interface connection for use with 0.32 mm ID columns (10 ferrules, 2 nuts)
SGE073202 SilTite metal - initial installation for GCMS interface connection for use with 0.45-0.53 mm ID columns, PK10
(10 ferrules, 2 nuts)
SGE073270 SilTite metal - initial installation for Thermo Scientific TRACE 1300 series GC split/splitless injectors for use with 0.10-0.25 mm ID columns
(10 ferrules, 2 nuts, 2 inlet base seals)
SGE073271 SilTite metal - initial installation for Thermo Scientific TRACE 1300 series GC split/splitless injectors for use with 0.32 mm ID columns
(10 ferrules, 2 nuts, 2 inlet base seals)
SGE073272 SilTite metal - initial installation for Thermo Scientific TRACE 1300 series GC split/splitless injectors for use with 0.45-0.53 mm ID columns
(10 ferrules, 2 nuts, 2 inlet base seals)
SGE073273 SilTite metal - initial installation for Thermo Scientific TRACE 1300 series GC split/splitless injectors for use with 1/32" columns
(10 ferrules, 2 nuts, 2 inlet base seals)
SGE073220 Replacement SilTite metal ferrules for all Thermo Scientific GCMS interface connections for use with 0.10-0.25 mm ID columns, PK10
SGE073221 Replacement SilTite metal ferrules for all Thermo Scientific GCMS interface connections for use with 0.32 mm ID columns, PK10
SGE073222 Replacement SilTite metal ferrules for all Thermo Scientific GCMS interface connections for use with 0.45-0.53 mm ID columns, PK10
SGE073219 Replacement SilTite metal ferrules for all Thermo Scientific GCMS interface connections for use with 1/32" columns, PK10
SGE073220 Replacement SilTite metal ferrules for Thermo Scientific TRACE 1300 series GC split/splitless injectors for use with 0.10-0.25 mm ID columns, PK10
SGE073221 Replacement SilTite metal ferrules for Thermo Scientific TRACE 1300 series GC split/splitless injectors for use with 0.32 mm ID columns, PK10
SGE073222 Replacement SilTite metal ferrules for Thermo Scientific TRACE 1300 series GC split/splitless injectors for use with 0.45-0.53 mm ID columns, PK10
SGE073219 Replacement SilTite metal ferrules for Thermo Scientific TRACE 1300 series GC split/splitless injectors for use with 1/32" columns, PK10
SGE073224 Replacement SilTite metal nuts for all GCMS interface connections, PK5
SGE073226 Replacement SilTite metal nuts for Thermo Scientific TRACE 1300 series GC split/splitless injector, PK5
SGE073400 Replacement SilTite base seals For Thermo Scientific TRACE 1300 series GC split/splitless injector, PK2
SGE073401 Replacement SilTite base seals For Thermo Scientific TRACE 1300 series GC split/splitless injector, PK10
For use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface, Agilent MS interface
SGE073219 SilTite ferrules for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interface for use with 1/32" columns, PK10
SGE073220 SilTite ferrules for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interface for use with 0.10-0.25 mm ID columns, PK10
SGE073221 SilTite ferrules for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interface for use with 0.32 mm ID columns, PK10
SGE073222 SilTite ferrules for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interface for for use with 0.45-0.53 mm ID columns, PK10
SGE073223 SilTite ferrules 1/16", for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard MS interface,
Agilent MS interface, PK10
SGE073200 SilTite metal - initial installation for 0.10-0.25 mm ID columns (10 ferrules, 2 nuts)
SGE073201 SilTite metal - initial installation for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard
MS interface, Agilent MS interface for use with 0.32 mm ID columns (10 ferrules, 2 nuts)
SGE073202 SilTite metal - initial installation for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard
MS interface, Agilent MS interface for use with 0.45-0.53 mm ID columns (10 ferrules, 2 nuts)
SGE073203 SilTite metal - initial installation 1/16" for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard
MS interface, Agilent MS interface (10 ferrules, 2 nuts)
SGE073224 SilTite metal nuts 10/32" 0.8 mm ID for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard
MS interface, Agilent MS interface, PK5
SGE073225 SilTite metal nuts 10/32" 1/16" ID for use on PerkinElmer MS interface, Shimadzu QP5000/5050 wide bore MS interface, QP2010 injector and QP2010 standard
MS interface, Agilent MS interface, PK5
SGE073226 SilTite metal nuts

 

Selection Guide - GC Ferrules

SilTite® Metal Ferrules

SilTite™ Metal FerrulesSilTite metal ferrules have been developed specifically for use with GC-MS systems and have distinct advantages over graphite
and composite ferrules for use with GC-MS interfaces:

  • SilTite ferrules form a strong permanent airtight seal around the capillary column.
  • The metal SilTite ferrule and nut are made from the same material and therefore have the same thermal expansion
        coefficient. As the oven heats up and cools down, the nuts and ferrules expand and contract at the same rate, eliminating
        annoying leaks and the need to retighten the ferrule after installation.
  • The base of the SilTite ferrule is flat and forms a perfect seal with the MS interface, covering the whole transfer interface.
  • Specifically designed non-Swagelok SilTite nuts, characterized by two notches on the outer surface of the nut.
        The inner taper of the nut corresponds to the angle of the SilTite ferrule, ensuring an even closure of the ferrule around the whole
        column eliminating leaks.
  • SilTite nuts are reusable. Unlike graphite Vespel® ferrules that are nearly impossible to remove from the nuts after use,
        SilTite ferrules are easily removed from the specially designed nut while still attached to the capillary column.
  • SilTite metal ferrules have a temperature tolerance well above the limit of the injector, MS interface or GC oven.
  • SilTite nuts and ferrules are available for most major GC-MS instrument interfaces.
  • Removes contamination caused by Vespel or graphite ferrules.
  • Reduced air background gives a cleaner spectra with better library matches.


100% Graphite GC Ferrules

Trajan 100% Graphite GC FerrulesGraphite GC ferrules are made from high purity exfoliated graphite.  They seal with minimal torque and are reusable if they are not over tightened.  Graphite GC ferrules do not shrink in use but are very soft and must be packed and handled with care.

Graphite ferrules are commonly used in GC systems on the linlet and detector ends because they don't stick to the column, and can be removed and reinserted easily.  They should not be used with GC/MS instruments because of permeability to air.

You should always trim a short piece of the column after replacing the ferrule to be sure that no graphite particles have plugged the column.

Upper temperature limit of 450°C.


100% PTFE GC Ferrules

Tragan 100% PTFE GC FerrulesPTFE GC ferrules are made from 100% PTFE.  They are soft, completely inert, and have very low friction. 
PTFE GC ferrules are hydrophobic and commonly used in liquid applications.

Upper temperature limit of 250°C.



100% Vespel GC Ferrules

Trajan 100% Vespel GC FerrulesVespel GC ferrules are made from 100% high-temperature polyimide, a hard polymeric material that tends to seal permanently to capillary columns when in use.  A firm torque is required to compress and seal.  They are not reusable and tend to shrink through repeated heating and cooling cycles.

Vespel GC ferrules are excellent for creating seals on metal or glass and have long lifetimes.  100% Vespel is essentially non-porous
to oxygen so it is ideal for GC-MS interface use, where air permeation can raise the background signal and contribute to phase degradation. 
They also work best in connections that are isothermal or insulated from oven temperature changes.

Upper temperature limit of 350°C.



Vespel-Graphite (85% Vespel / 15% graphite) and (60% Vespel / 40% graphite) GC Ferrules

Trajan Vespel Graphite GC Ferrules

Vespel/graphite GC ferrules are made from quality polyimide/graphite blend.  They seal with minimal torque and can be reused and repositioned along capillary columns if not over compressed in the fitting.  Due to slight shrinking at high temperatures, they must be retightened after initial temperature cycles to avoid leaks.

Two types of Vespel/graphite are commonly used, one with 40% graphite and one with 15% graphite.  They are ideal for GC-MS interface applications because they are non-porous to oxygen.  The inclusion of graphite increases high-temperature tolerance and
reduces sticking and shrinkage.

Trajan offers both Vespel/graphite blends, a 60/40 mix and an 85/15 mix.  The 85/15 maintains a high level of hardness and long lifetime. 
The 60/40 blend is softer, with improved wear resistance and lower friction. These ferrules will require less force to compress and form a seal.


Still Have Questions?

You can give us a call or email us and we can find the right ferrule for your application.  It's our pleasure to help you and it's free!

1-800-267-8103 or tech@chromspec.com