Gas Purification Filters and Traps

Why GC Manufacturers Recommend Using Gas Traps...

  • Eliminate contaminants (oxygen, hydrocarbons and moisture).
  • Increase column lifetime and reduce detector interference.
  • Decrease baseline noise, increase sensitivity and improve analytical accuracy.

Gas traps are more effective if they are mounted in a vertical position with the carrier gas running upwards through the trap.
This eliminates channeling of the carrier gas and maximizes the trapping capacity.

CHROMSPEC™ Indicating Moisture Traps

CHROMSPEC™ Indicating Moisture Traps

CHROMSPEC™ moisture traps utilize polycarbonate bodies, more inert and resistant to infusion than the acrylic used by other manufacturers. These traps are refillable and available in three sizes with three different adsorbent combinations. The ends are provided with Swagelok™ tube fittings. Each end fitting includes a 40 micron sintered stainless steel frit. 

  • Inert polycarbonate body.
  • Simultaneous removal of H2O.
  • Combination molecular sieve 13X and indicating 4A.
  • Indicating 4A changes colour from blue to tan at 20% relative humidity.
  • Maximum pressure is 125 psi.

Molecular Sieves 13X and Indicating 4А are the adsorbents most commonly employed for gas drying in gas chromatography.
The indicating 4A changes from blue to tan at 20% relative humidity. 

Size End Fitting Capacity Efficiency Item Number
120cc 1/8" 22gm <25ppb C36000
200cc 1/8" 36gm <20ppb C36010
200cc 1/4" 36gm <20ppb C36015
400cc 1/8" 72gm <15ppb C36035
400cc 1/4" 72gm <15ppb C36040
Moisture Trap Refill - 1 pint C36030
Moisture Trap Refill - 1 gallon C36129

Molecular Sieves 5A and Indicating Drierite™ mixture will remove oil and hydrogen sulfide as well as moisture.
The indicating Drierite™ changes from blue to pink as relative humidity approaches 40%.


CHROMSPEC™ Hydrocarbon Traps & Hydrocarbon Moisture Traps

CHROMSPEC™ Hydrocarbon Traps &amp; Hydrocarbon Moisture Traps

Traps utilize a very high surface area activated carbon. Designed to remove alcohols, ethers, chlorinated hydrocarbons, ketones and aromatics

  • Refillable traps are available in several configurations.
  • Trap body is one piece spun aluminum.
  • The standard model contains 200cc of filtering medium.
  • Each Swagelok™ end fitting includes a 40 micron stainless steel frit.
  • Maximum pressure is 250 psi.

 

 

Trajan/CRS ZPure™ Glass O2 Gas Filter with logo

Trajan – CRS ZPure™ Glass O2 Gas Filters

Compact indicating purifiers for high-efficiency oxygen removal.

  • Suitable for use with chromatography carrier gas streams.
  • Remove oxygen to low-ppb levels.
  • Recommended as downstream indicator for high-capacity oxygen purifiers.
  • Change colour from green to gray when adsorption capacity is depleted.
  • Allow high-capacity removal of oxygen with the benefit of an indicator to alert the user
        of saturation of the primary 
    trap.
  • Form copper oxide in the presence of oxygen; no gas is generated.
  • Inner glass tube is protected by a sealed outer plastic tube.
  • If the glass tube were to fail, the gas system is still fully protected against leaks.
This item ships as a hazardous small quantity exception.

Product Numbers

ZPure Glass O2 Filter 46 cc 1/8” Brass C37236B

ZPure Glass O2 Filter 46 cc 1/4” Brass C37237B

ZPure Glass O2 Filter 46 cc 1/8” Stainless Steel C37236SS

ZPure Glass O2 Filter 46 cc 1/4” Stainless Steel  C37237SS

These Oxygen Filters are also available with quick connect fittings.

Quick Connect 

ZPure Glass O2 Filter, 1/8" Brass Quick Connect Fittings C37236BQC

ZPure Glass O2 Filter, 1/4" Brass Quick Connect Fittings C37237BQC

ZPure Glass O2 Filter, 1/8" Stainless Steel Quick Connect Fittings C37236SSQC

ZPure Glass O2 Filter, 1/4" Stainless Steel Quick Connect Fittings C37237SSQC

         


Advanced Filter System (AFS) Gas Traps

Economically Priced Replacement Traps for Your Existing Agilent Gas Purification

Trajan - CRS Advanced Filter System (AFS) Gas Traps

System Applications: GC and GC-MS, ECD, ICP

Trajan/CRS's high-capacity gas purifying system is designed to reduce contaminants in gases commonly used in laboratory applications to low-ppb levels, available in two models. The AFS Purifier I removes oxygen, moisture and hydrocarbons, (greater than C4) from inert gases and hydrogen. It contains high-sensitivity oxygen and moisture indicator. When cartridge is depleted the oxygen indicator changes from GREEN to GREY. The Moisture indicator changes from BLUE to BROWN. Both AFS Purifier I and AFS Purifier II have a very high capacity and can be expected to supply four GC's for at least one year when used with 99.995% pure gas supplies (provided reasonable care is taken during tank changes). 

The Advanced Filter System Complete Kit includes the AFS Cartridge, Manifold, and the wall and bench mounting brackets.

  • Removes oxygen, hydrocarbons and moisture.
  • High capacity and efficiency in a single cartridge.
  • Can supply 4 GCs for at least one year when used with 99.995% pure gas.
  • Easy cartridge replacement – twist on/off.
  • Double seal construction for safety, especially for use with hydrogen.
  • Check valves protect gas lines from ambient air during cartridge replacement, maximizing column and system lifetime. 

     



Restek Click-On In-Line Super Clean Carrier Gas Purification Kit with Logo

Click-On In-Line Super Clean Carrier Gas Purification Kit

  • High-purity output ensures 99.9999% pure gas.
  • Click-On fittings for easy, leak-tight cartridge changes; brass or stainless steel, 1/4” or 1/8”.
  • Triple gas trap is ideal for purifying carrier gas – it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.
  • Fuel gas trap is ideal for purifying flame ionization detector (FID) fuel gases, removing both moisture and hydrocarbons.
  • Helium-specific triple gas trap is ideal for GC-MS – it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.

     


 

VICI Metronics Gas Specific Purifiers and Gas Traps with logo

VICI® Metronics Gas Specific Purifiers and Gas Traps

Gas purity is essential in any application requiring extreme sensitivity. VICI Metronics gas traps and gas purifiers for specific gases dramatically reduce the levels of contaminants, enhance the purity of lower grade helium, and help ensure instrument stability, reproducibility, and lower maintenance costs.

  • Produce better than 99.9999% purity from a 99.995% cylinder
  • Provide point-of-use gas purification of helium, hydrogen, methane, nitrogen, carbon dioxide, or air
  • Reduce gas impurities from high PPM to low PPB levels
  • Decrease baseline noise and increase GC/MS sensitivity
  • Replace three traps with one purifier.

                                                            

     

Mounting Clips

CHROMSPEC Mounting ClipsThese mounting clips fit Trigon gas purifiers.  They help remove line stress from the trap, especially important with glass-bodied models, and make for a far neater installation.  All mounting clips are made from black thermoplastic except the TTC-5, which is vinyl coated spring steel.



Still Have Questions?

You can give us a call or email us and we can help guide you through the process. It's our pleasure to help you and it's free!

1-800-267-8103 or tech@chromspec.com